1001 S Main Street STE 500 Kalispell, MT
24/7 Urgent Call: +1-406-2251570

Radiology Billing: Global, 26 and TC, the Imaging MPPR, and Contrast Codes

18 min read Medical Billing 2026 Guide
A flat illustration of a radiologist reading an MRI brain scan beside an imaging scanner and a claim form, no text in the image

Direct answer: Every diagnostic imaging study has two components, and radiology billing turns on one question per study: which component did you actually earn. The technical component pays for performing the study, the equipment, the technologist and the supplies, and the professional component pays for the radiologist interpretation and the written report. When one practice owns the equipment and employs the radiologist who reads the study, it bills the study globally, with no modifier, and collects both components. When a radiologist only interprets a study performed somewhere else, the radiologist bills the professional component with modifier 26. When an imaging center owns the scanner but contracts the reads out, it bills the technical component with modifier TC. On top of that component question sit three payment mechanics that decide what is actually paid: the multiple procedure payment reduction on same-session diagnostic imaging, the contrast split where MRI brain without contrast (70551), with contrast (70552) and without-then-with contrast (70553) are three distinct codes, and the equipment modifiers that cut payment when a scanner or an x-ray method does not meet the current standard.

THE THREE ARRANGEMENTS: GLOBAL, 26 AND TC

There are three arrangements that cover most radiology billing, and the correct one is decided by the setting, not by what the template defaults to. A group that owns its equipment and employs the reading radiologist bills for both components and reports the study globally with no component modifier. A group that only interprets studies performed somewhere else reports the professional component with modifier 26. A free-standing imaging center or independent diagnostic testing facility that owns the scanner but contracts the reads out reports the technical component with modifier TC. The hospital case is the one most often stated wrongly, so it deserves its own rule. When a study is furnished to a hospital patient, the Medicare contractor will not pay a supplier for the technical component, because the hospital is paid for it, but the radiologist interpretation is still paid under the physician fee schedule, in all settings, as long as it is an identifiable, direct and discrete service to an individual patient with a written report. That is the Medicare Claims Processing Manual, Chapter 13, sections 20.1 and 20.2.1. The hospital does not capture a global payment, and the radiologist does not bill nothing. For more on how the two components split, see Modifier 26 vs TC: Professional and Technical Components.

ArrangementWho bills whatHow it is reported
Own the equipment and employ the readerBoth components, technical and professionalGlobally, with no modifier
Interpret only, study performed elsewhereProfessional component onlyModifier 26
Own the scanner, contract the reads outTechnical component onlyModifier TC
Hospital patientHospital is paid for the technical component, radiologist bills the interpretationRadiologist reports modifier 26, with a written report

NEVER BILL GLOBAL AND 26 OR TC FOR THE SAME STUDY

Billing a study globally and then adding modifier 26 or TC for the same service is double billing, and it has been flagged as an overpayment pattern by the Office of Inspector General. The global code already contains both components, so a second line for one of them charges the payer twice for the same work. This error usually comes from a template that defaults to global and a coder who adds a component modifier out of habit, or from two systems each reporting part of the same study without checking what the other one sent. Before a claim goes out, check that each study appears once, either as a global line, a 26 line, or a TC line, and never as a global line plus a component line. When a practice and an outside facility both touch the same study, confirm in writing which side is billing which component, because the payer will pay the first claim it sees and deny the second as a duplicate.

THE IMAGING MPPR

When two or more diagnostic imaging procedures are furnished in the same session on the same day to the same patient by the same physician or by physicians in the same group practice, Medicare applies the multiple procedure payment reduction, known as the MPPR, to the second and later studies. The highest-priced study is paid in full, and the reduction falls on the extras. The technical components of the second and subsequent procedures are reduced by 50 percent, because the clinical labor and supplies are mostly not furnished twice. The professional components of the second and subsequent procedures are reduced by 5 percent, so they are paid at 95 percent of the fee schedule amount. The two reductions are applied separately to each component, which is why a globally billed study and a split-billed study end up reduced the same way. The imaging MPPR reaches across modalities rather than only within one family, so a CT and an MRI in the same session can both be affected. Two useful exceptions are mammography, where codes 77065, 77066 and 77067 are not flagged for the imaging MPPR at all, and plain x-rays, which are not in the imaging family. For how the standard multiple procedure rules compare, see Modifier 51: Multiple Procedures Billing.

THE 5 PERCENT PROFESSIONAL COMPONENT RULE, VERIFIED AGAINST THE CMS SOURCE

Sources disagree on the professional component reduction for subsequent studies, and the disagreement has a clear cause. An older AAPC piece on multiple procedure payment reduction reflects the rule as it stood before 2017, when the professional component reduction was 25 percent. The current Medicare rule is different, and it was verified at writing time against the CMS source, CMS Transmittal 3578, Change Request 9647, Multiple Procedure Payment Reduction on the Professional Component of Certain Diagnostic Imaging Procedures. Section 502(a)(2) of the Consolidated Appropriations Act of 2016 revised the professional component reduction for the second and subsequent procedures from 25 percent to 5 percent of the physician fee schedule amount, effective 1 January 2017, and the transmittal states that the reduction on the technical component remains at 50 percent. So the current rule is 50 percent off the technical component of extras and 5 percent off the professional component of extras, and the older 25 percent figure is history, not the current rule. Do not quote 25 percent on a current claim, and do not let an old guide or an old template override the transmittal.

THE MPPR INDICATORS 0 THROUGH 5

CMS flags each code in the physician fee schedule relative value file with a multiple procedure indicator that says which reduction, if any, applies. Indicator 4 is the diagnostic imaging reduction, and it applies to over 100 codes, with the reductions applied separately to the professional and technical components. The indicators most often seen on imaging claims are 0 through 5.

IndicatorMeaning
0No reduction applies
1Does not apply to any current codes, used before 1995
2Standard multiple procedure reductions
3Endoscopic reductions
4Diagnostic imaging reduction, applied separately to the professional and technical components
5Therapy reductions

Additional indicators exist for other service types, including diagnostic cardiovascular services and diagnostic ophthalmology services. Before billing two studies in one session, check the multiple procedure indicator on each code in the current physician fee schedule relative value file, because the indicator, not the code family, decides whether the reduction applies. The older diagnostic imaging family framing that some guides still quote is stale: CMS stopped populating the eleven family indicators for services furnished on or after 1 January 2011 and now flags the affected codes with a single indicator.

THE CONTRAST SPLIT, 70551, 70552 AND 70553

MRI and CT exam codes split into distinct CPT codes by contrast use, and each code has its own fee schedule amount, so picking the wrong one changes the payment. MRI brain without contrast is 70551, MRI brain with contrast is 70552, and MRI brain without contrast followed by contrast material and further sequences is 70553. These are three distinct codes, not three ways of describing the same study. Report the code that matches what was actually done: if no contrast was given at any point, use 70551; if contrast was given and no pre-contrast images were obtained, use 70552; if pre-contrast images were obtained and then contrast was given for post-contrast images, use 70553. Never bill 70551 and 70552 together for the same session, because 70553 already includes both sets of sequences, and Medicare makes no separate payment for 70551 furnished in the same session as 70553. The same three-way pattern repeats across other anatomies: CT brain is 70450 without contrast, 70460 with contrast and 70470 without-then-with; MRI lumbar spine is 72148, 72149 and 72158; lower-extremity joint MRI is 73721, 73722 and 73723. The contrast material itself is usually reported separately with a HCPCS Level II code, for example a gadolinium-based agent code for MRI, depending on the payer and the site of service, and oral or rectal contrast alone does not qualify a study as with contrast.

CodeStudyContrast
70551MRI brain, including brain stemWithout contrast material
70552MRI brain, including brain stemWith contrast material
70553MRI brain, including brain stemWithout contrast material, followed by contrast material and further sequences

EQUIPMENT MODIFIERS THAT CUT PAYMENT: CT AND X-RAY

Three modifiers reduce payment when the equipment or the method does not meet the current standard, and all three act on the technical component, so they are easy to miss on a globally billed claim where the cut is buried in the total. A CT study performed on equipment that does not meet the NEMA XR-29 standard carries the CT modifier, and the technical component is reduced by 15 percent. An x-ray taken using film carries modifier FX, and the technical component is reduced by 20 percent. An x-ray taken using computed radiography carries modifier FY, and the technical component is reduced by 10 percent. These are not coding choices, they are facts about the equipment, and the modifier must match the machine that actually took the image. A practice that upgrades its CT to meet the standard, or that retires film, should confirm the modifiers are removed from the charge description master at the same time, because a stale modifier keeps cutting payment after the equipment problem is gone.

ModifierSituationPayment effect on the technical component
CTCT equipment does not meet the NEMA XR-29 standardReduced by 15 percent
FXX-ray taken using filmReduced by 20 percent
FYX-ray taken using computed radiographyReduced by 10 percent

LATERALITY: LT, RT AND MODIFIER 50

Laterality modifiers are required on unilateral extremity x-ray codes, and leaving them off is a common avoidable denial. Report LT for the left side and RT for the right side on a study of one extremity. When the same study is performed on both sides, report the code once with modifier 50 for a bilateral procedure, which is paid at 150 percent of the fee schedule amount, rather than reporting the code twice. Do not report the code twice with LT on one line and RT on the other when the payer wants a single bilateral line, and do not append LT or RT to a code that is already bilateral by definition. Check the code descriptor first: some codes are inherently bilateral, and adding a laterality modifier to those is an error.

PRIOR AUTHORIZATION AND THE RADIOLOGY BENEFIT MANAGER

For commercial plans, the largest gate before payment is prior authorization, and it usually runs through a radiology benefit manager. Many commercial plans require approval before an advanced imaging study such as MRI, CT or PET is performed, and the request must show the clinical indication, the prior studies already done, and why the requested study is the right next step. A study performed without a required authorization is denied even when it was medically necessary, and a retroactive authorization is not always available, so the authorization must be in hand before the patient is scanned. Build the check into scheduling: confirm the authorization number, the approved CPT code and the approved date range before the appointment, and re-check the authorization when the ordering physician changes the study, because an authorization for 70551 does not cover a 70553. Medicare is different on one point that still confuses coders: the Medicare Appropriate Use Criteria program for advanced imaging is not in force. CMS paused the program and rescinded its regulations effective 1 January 2024, so Medicare claims no longer carry Appropriate Use Criteria information.

DOCUMENTATION THAT SURVIVES AN AUDIT

The written report is what earns the professional component, and without it there is no interpretation to bill. The report must identify the patient and the study, describe the technique and the contrast used, give the findings, and end with an impression that answers the clinical question. The technologist log should show the contrast administration, the dose and the time, because a 70553 claim with no contrast in the log invites a recoupment. Keep the order, the medical necessity note, the prior authorization number for commercial plans, and the equipment record that supports or removes the CT, FX and FY modifiers in the same file as the report, so an auditor can follow the claim from the order to the code without asking for missing pieces.

WORKED EXAMPLE, ALL FIGURES ILLUSTRATIVE

Every figure in this example is illustrative. A patient has two MRI studies in the same session on the same day, read by the same group. The first is MRI brain without contrast followed by contrast, code 70553, with an illustrative technical component of 300 dollars and an illustrative professional component of 100 dollars. The second is MRI lumbar spine without contrast, code 72148, with an illustrative technical component of 200 dollars and an illustrative professional component of 80 dollars. The imaging MPPR ranks the studies by fee schedule amount, so 70553 is the highest-priced study and is paid in full: technical component 300 dollars and professional component 100 dollars. The second study is reduced: its technical component is cut by 50 percent, from 200 dollars to 100 dollars, and its professional component is cut by 5 percent, from 80 dollars to 76 dollars. The illustrative total for the session is 400 dollars of technical component and 176 dollars of professional component, or 576 dollars in all. In a second example, a radiologist reads a 70553 study performed on a hospital inpatient. The radiologist bills 70553 with modifier 26 only, for the interpretation and the written report, and bills no technical component and no global code, because the hospital is paid for the technical component.

COMMON MISTAKES THAT TRIGGER DENIALS

The first common mistake is billing a study globally and adding modifier 26 or TC for the same service, which is double billing and an overpayment pattern. The second is billing 70551 and 70552 together instead of using 70553 for a without-then-with study. The third is coding a without-then-with study as 70551, which gives up the difference between the two fee schedule amounts, or coding a without-only study as 70553, which invites a recoupment when the contrast administration is absent from the report and the technologist log. The fourth is forgetting that the imaging MPPR cuts the second and later studies in the same session, and then chasing a denial that is actually a correct reduction. The fifth is quoting the old 25 percent professional component reduction instead of the current 5 percent rule verified against CMS Transmittal 3578. The sixth is leaving the CT, FX or FY modifier off a study that requires it, or leaving it on after the equipment has been upgraded. The seventh is omitting LT or RT on a unilateral extremity x-ray, or reporting a bilateral study twice instead of once with modifier 50. The eighth is performing an advanced imaging study for a commercial plan without the radiology benefit manager authorization in hand. The ninth is billing a hospital patient study globally, or billing nothing at all, instead of billing the interpretation with modifier 26 and a written report. Each of these is preventable by checking three things before the claim goes out: who earned which component, whether another study was done in the same session, and what the contrast and equipment records actually show.

CHECKLIST

Confirm who earned each component before choosing global, 26 or TC, and never report a study as both global and a component. For a hospital patient, bill the interpretation with modifier 26 and a written report, and do not bill the technical component. Rank same-session imaging studies by fee schedule amount, pay the highest in full, reduce the technical components of the extras by 50 percent and the professional components by 5 percent, and remember the current 5 percent rule from CMS Transmittal 3578, not the old 25 percent figure. Check the multiple procedure indicator on each code in the current physician fee schedule relative value file, and remember that indicator 4 applies separately to the professional and technical components. Pick the contrast code that matches what was actually done: 70551 without contrast, 70552 with contrast, 70553 without-then-with, and never bill 70551 and 70552 together. Add the CT modifier when CT equipment does not meet the NEMA XR-29 standard, FX for film x-ray and FY for computed radiography, and remove a stale modifier when the equipment is upgraded. Append LT or RT to unilateral extremity x-rays, and report a bilateral study once with modifier 50 at 150 percent of the fee schedule amount. Confirm the radiology benefit manager authorization, the approved code and the date range before scanning a commercial patient, and remember that the Medicare Appropriate Use Criteria program was paused and its regulations rescinded effective 1 January 2024, so Medicare claims no longer carry that information. Make sure the written report answers the clinical question and the technologist log shows the contrast administration. Verify the current rule against the CMS manuals and the specific payer policy before acting, because codes and coverage rules change over time.

FREQUENTLY ASKED QUESTIONS

When do I bill a radiology study globally? Bill globally, with no modifier, when one practice owns the equipment and employs the radiologist who reads the study, so the same entity earned both the technical and the professional component. When do I use modifier 26? Use modifier 26 when you only interpret a study performed somewhere else, so you are billing the professional component only. When do I use modifier TC? Use modifier TC when you own the scanner and performed the study but contracted the interpretation out, so you are billing the technical component only. Can I bill global and 26 for the same study? No. The global code already contains both components, so adding 26 or TC for the same service is double billing and has been flagged as an overpayment pattern. How does the imaging MPPR work? When two or more diagnostic imaging procedures are furnished in the same session on the same day to the same patient by the same physician or group, the highest-priced study is paid in full, the technical components of the extras are reduced by 50 percent, and the professional components of the extras are reduced by 5 percent. Is the professional component reduction 25 percent or 5 percent? The current Medicare rule is 5 percent, verified against CMS Transmittal 3578, Change Request 9647, effective 1 January 2017. The 25 percent figure applied from 2012 through 2016 and is no longer current, so do not quote it on a current claim. What is the difference between 70551, 70552 and 70553? They are three distinct MRI brain codes: 70551 is without contrast, 70552 is with contrast, and 70553 is without contrast followed by contrast and further sequences. Never bill 70551 and 70552 together for the same session. What happens if my CT scanner does not meet the NEMA XR-29 standard? The study carries the CT modifier and the technical component is reduced by 15 percent. What are modifiers FX and FY? FX is for an x-ray taken using film, with the technical component reduced by 20 percent, and FY is for an x-ray taken using computed radiography, with the technical component reduced by 10 percent. Do I still need to report Appropriate Use Criteria information on Medicare claims? No. CMS paused the Appropriate Use Criteria program and rescinded its regulations effective 1 January 2024, so Medicare claims no longer carry that information. When do I use LT, RT and modifier 50? Use LT or RT on unilateral extremity x-rays, and report a bilateral study once with modifier 50, which is paid at 150 percent of the fee schedule amount. Do commercial plans require prior authorization for advanced imaging? Many do, usually through a radiology benefit manager, and a study done without a required authorization is denied even when it was medically necessary, so confirm the authorization, the approved code and the date range before the patient is scanned. What does the hospital rule mean for the radiologist? When a study is furnished to a hospital patient, the hospital is paid for the technical component, but the radiologist interpretation is still paid under the physician fee schedule with a written report, under the Medicare Claims Processing Manual, Chapter 13, sections 20.1 and 20.2.1.

A note on codes and coverage: This article is educational information about medical billing rules, not legal, financial or compliance advice. Codes, coverage rules and payer policies vary and change over time, so always verify the current rule against the CMS manuals and the specific payer policy before acting. The worked example uses illustrative figures only. The current professional component reduction of 5 percent for subsequent diagnostic imaging procedures was verified against CMS Transmittal 3578, Change Request 9647, effective 1 January 2017.

Having trouble with radiology billing, or with global, 26 and TC denials? Neximed Billing provides denial management, corrected claim review and billing workflow support. Contact us at info@neximedbilling.com or +1-406-2251570.

Related reading: Modifier 26 vs TC: Professional and Technical Components · Modifier 51: Multiple Procedures Billing · Claim Denial Codes: Complete Guide