Sleep Study Billing: In-Lab Polysomnography 95810 vs Home Sleep Test G0398

THE SHORT ANSWER
Where the test happened decides the code family, and for a home test the payer decides the code set. An attended, in-lab polysomnography study bills with CPT codes 95808, 95810 or 95811, and it can never be billed for a study done at home or in a mobile unit. An unattended home sleep test bills with CPT codes 95800, 95801 or 95806 for most commercial payers, but Medicare wants its own HCPCS codes for the same studies: G0398, G0399 or G0400, matched to the type of portable monitor used. Submitting a CPT home test code to a Medicare contractor that requires the G-codes is a code-set error that denies before medical necessity is ever reviewed, so the payer rule has to be checked before the claim is built, not after it denies.
Two forks sit on top of each other: facility or home, then CPT or G-code by payer for a home test. Both mistakes are preventable, and both are among the most common reasons sleep study claims deny. The rest of this guide works through both forks in order, then the codes inside each family, then the technical and professional split, then the CPAP coverage that follows from the study result.
THE TWO FORKS THAT DECIDE EVERY SLEEP STUDY CLAIM
Every sleep study code sorts into one of two buckets before anything else about the patient matters: attended, facility-based polysomnography, or unattended, portable home testing.
| Fork | Question | Answer decides |
|---|---|---|
| First fork: setting | Was the study attended by a technologist in a facility-based sleep laboratory, or unattended at home with a portable monitor the patient applied | Which code family is eligible at all |
| Second fork: payer code set | For a home test, does this payer want CPT codes 95800, 95801 and 95806, or HCPCS G-codes G0398, G0399 and G0400 | Which code from the home family goes on the claim |
| Where the test happened | Eligible codes | Governed by |
|---|---|---|
| Facility-based sleep laboratory, technologist-attended | 95807, 95808, 95810, 95811 (CPT) | Facility-only requirement; never billable for a home or mobile study |
| Home, unattended, patient self-applies the device | G0398, G0399, G0400 (HCPCS) or 95800, 95801, 95806 (CPT), depending on payer | Payer-specific mandate; this is the fork that causes most denials |
Before choosing any code, read two facts from the report: where the study was performed, and which payer will receive the claim. If either fact is missing, the code cannot be chosen yet.
FORK ONE: THE FACILITY-ONLY RULE FOR POLYSOMNOGRAPHY
Medicare coverage articles state the facility requirement in unambiguous terms. Per the CMS billing and coding article on polysomnography and other sleep studies, documentation must show that polysomnography billed under 95808, 95810 or 95811 was performed in a facility based sleep study laboratory and not in the home or a mobile facility. The article is at https://www.cms.gov/medicare-coverage-database/view/article.aspx?articleId=57049&ver=13 and every Medicare Administrative Contractor version carries the same restriction, as does the companion article at https://www.cms.gov/medicare-coverage-database/view/article.aspx?articleid=57496&ver=14
That wording has a practical consequence that no modifier can fix. A claim for 95810 or 95811 with a place-of-service code indicating the patient home, or with a chart note describing a portable monitor rather than a laboratory visit, describes a service the code does not cover. Modifier 52 for reduced services does not cure it, modifier 26 for the professional component does not cure it, and a strong medical necessity argument does not cure it, because the problem is not medical necessity. The problem is that the code requires a facility-based, attended study and the record shows something else. The correct action is to recode the study into the home family if the study was in fact a home test, or to hold the claim and correct the documentation if the study really was in the lab and the record says otherwise.
A freestanding laboratory that is not part of a physician practice usually enrolls with Medicare as an independent diagnostic testing facility, known as an IDTF, to bill the technical component, while a hospital-based laboratory bills its technical component on its own facility claim. Enrollment and accreditation requirements differ by contractor, so the laboratory should confirm its own contractor rules in writing.
There is also a clinical fork underneath the billing forks. A home test is appropriate for patients with a high pretest probability of moderate to severe obstructive sleep apnea, evaluated first in a comprehensive sleep evaluation, and the CMS article requires documentation to show both. A home test ordered without that evaluation, or for a patient whose suspected condition is not sleep apnea at all, is a medical necessity problem before it is a billing problem.
THE IN-LAB CODES: 95807, 95808, 95810 AND 95811
The attended in-lab family has four codes, and three questions settle which one applies: was sleep staged, how many additional parameters were recorded beyond staging, and was positive airway pressure titration started during the night. Sleep staging means scoring sleep from EEG, EOG and submental EMG. The additional parameters are counted only after those three staging signals. Oxygen saturation, airflow, respiratory effort, leg movement, ECG and body position each count as one additional parameter.
| Code | Sleep staging | Additional parameters | Age | Typical use |
|---|---|---|---|---|
| 95807 | No | Four named parameters: ventilation, respiratory effort, ECG or heart rate, oxygen saturation | Any age | Attended limited-channel study without staging |
| 95808 | Yes | 1 to 3 | Any age | Attended polysomnography with a short channel set |
| 95810 | Yes | 4 or more | Age 6 years or older | Attended polysomnography, the standard full in-lab study |
| 95811 | Yes | 4 or more, with initiation of CPAP or bilevel ventilation | Age 6 years or older | Split-night study or full titration night |
| 95782 and 95783 | Yes | 4 or more | Younger than 6 years | The under-6 counterparts of 95810 and 95811 |
CPT 95810 is the workhorse code. It describes polysomnography of at least six hours, with continuous, simultaneous recording of sleep staging plus four or more additional physiologic parameters, typically airflow, respiratory effort, oxygen saturation, ECG or heart rate, and limb movement, attended by a technologist, for patients age 6 years or older. A study that records fewer than four additional parameters is not a 95810, even if it ran all night in a laboratory. Count the channels in the report, not the channels the laboratory usually runs.
CPT 95808 covers polysomnography at any age, with sleep staging and 1 to 3 additional parameters of sleep, attended by a technologist. It has no age limit, unlike 95810 and 95811, which start at age 6. The channel count in the sleep report decides the code, and the decision is made after the study, from what was actually recorded, not from what was ordered.
CPT 95807 is the attended study without sleep staging. It records ventilation, respiratory effort, ECG or heart rate, and oxygen saturation, attended by a technologist, but sleep is not staged. Because polysomnography is defined by the inclusion of sleep staging, a study without staging is not a polysomnogram, and it cannot be reported as one. If a polysomnogram and a sleep study are performed on the same day, the charges are combined under the appropriate polysomnography code rather than billed as two studies.
THE SPLIT-NIGHT RULE: 95811 ALONE, NEVER WITH 95810
A split-night study starts as a diagnostic study and switches to titration partway through the night, once enough diagnostic data has been collected to confirm sleep apnea and set the pressure. The billing rule for that night is simple and absolute: bill 95811 alone. CPT code 95811 is inclusive of 95810 for that night, and billing both codes for the same night will deny one of them, usually as a bundled or duplicate service. The CMS article states it directly: CPT code 95811 alone should be billed for split night studies, as CPT code 95811 in this instance is inclusive of CPT code 95810.
The same rule covers a full titration night: a study that includes CPAP or bilevel titration bills as 95811 instead of 95810. The presence of titration during the night is what moves the code, not the proportion of the night spent titrating. The report must show when titration began and why, so the split-night decision is visible to anyone reviewing the claim.
THE SIX-HOUR RULE AND MODIFIER 52
For a study to be reported as polysomnography, sleep must be recorded and staged and directly attended by a qualified technologist. The recording must run at least six hours. The CMS article states the rule plainly: report with modifier 52 if less than 6 hours of recording or in other cases of reduced services. Modifier 52 marks reduced services, and the record should explain why the study ended early, whether the patient asked to end it, left, or equipment failed and could not be restored.
A short study is not automatically a denied study, but it must be flagged. A five-hour study billed as a full 95810, with no modifier and no explanation, asks the payer to pay full price for a partial service, while the same study billed with modifier 52, a reduced charge and a note explaining the early end gives the payer the facts it needs to pay the reduced amount. The six-hour rule is measured by recording time, not by time in bed and not by total sleep time, and the same modifier logic reaches the home test codes: a home study cut short is also a reduced service, and the download data shows how long the device actually recorded.
THE HOME TEST CODES: 95800, 95801 AND 95806
Home sleep apnea testing, often called HSAT, uses unattended portable monitors. The patient applies the device at home, sleeps with it, and returns it for download and interpretation. The three CPT codes describe what the device actually recorded, not the brand of the device and not the type label on the box. The channel count and content in the downloaded data decide the code.
| Code | What it records | Setting |
|---|---|---|
| 95800 | Heart rate, oxygen saturation, respiratory analysis, and sleep time | Home, unattended |
| 95801 | At minimum heart rate, oxygen saturation, and respiratory analysis | Home, unattended |
| 95806 | Heart rate, oxygen saturation, respiratory airflow, and respiratory effort | Home, unattended |
CPT 95806 is the most common in practice: simultaneous recording of heart rate, oxygen saturation, respiratory airflow, and respiratory effort, unattended by a technologist. It records airflow and effort as separate channels but does not record sleep time. CPT 95800 adds the sleep time element to a similar recording, using respiratory analysis such as airflow or peripheral arterial tone. CPT 95801 is the minimum set: heart rate, oxygen saturation and respiratory analysis, without the sleep-time element and without the separate airflow and effort channels of 95806. The distinction between 95800 and 95801 turns on sleep time, and the distinction between 95801 and 95806 turns on what was recorded. None of these three codes records EEG, EOG or EMG, so none of them stages sleep. That limitation is the reason a home test cannot answer certain clinical questions, covered below in the section on what a home test cannot do.
A home study must also be a real study, not a device handed over without instruction. The CMS article requires documentation to show that the patient who undergoes a home sleep test received, prior to the test, adequate instruction on how to properly apply a portable sleep monitoring device. It also requires documentation to show that the home sleep test was accomplished with a Medicare-approved device, with the channels monitored described in the test report, and was performed by a physician meeting the training requirements in the coverage policy.
THE G-CODE FORK: G0398, G0399 AND G0400 FOR MEDICARE
Medicare created its own HCPCS Level II codes for home sleep testing, built around the American Academy of Sleep Medicine portable-monitor type classification. The three codes map to monitor type, and the distinction between them is channel count and content, not device brand, not price, and not what a supplier calls the device in a catalog.
| Code | Monitor type | Minimum channel requirement |
|---|---|---|
| G0398 | Type II | Minimum of 7 channels: EEG, EOG, EMG, ECG or heart rate, airflow, respiratory effort, and oxygen saturation |
| G0399 | Type III | Minimum of 4 channels: 2 respiratory movement or airflow channels, 1 ECG or heart rate channel, and 1 oxygen saturation channel |
| G0400 | Type IV | Minimum of 3 channels |
G0398 is essentially an unattended full polysomnogram, and it is the least common of the three in routine practice, because a Type II device records the staging signals at home. G0399 is the most commonly billed home test code in practice, covering the standard Type III portable monitor. G0400 covers the simplest Type IV monitors, which record a minimum of three channels. Billing the wrong G-code for the channel count actually recorded is its own denial reason, separate from the CPT-versus-HCPCS mix-up. A Type III study billed as G0398 claims seven channels that were never recorded, and a Type II study billed as G0400 understates what was done and misstates the device type.
The practical rule most billing teams operate on is short: Medicare requires G0398, G0399 or G0400 for home sleep testing, and CPT 95800, 95801 or 95806 submitted to Medicare will deny. That short rule is the safe way to run a billing desk, and it matches what the CMS coverage articles list as the home sleep test codes. The full picture has one qualification worth knowing. The CPT-versus-G-code decision is partly contractor-specific: at least one Medicare Administrative Contractor, CGS Administrators, requires the most specific G-code in its current local coverage article, even though the same article also lists CPT 95800, 95801 and 95806 as generally allowed, while other contractors currently permit either code set. The safe course is to bill the G-code to Medicare in every jurisdiction, because the G-code is accepted everywhere Medicare home testing is covered, while the CPT code is accepted only in some jurisdictions.
Commercial payers split the other way: most accept the CPT home-testing codes, while a real minority, including some commercial plans and some Medicaid programs, crosswalk to the G-codes instead. Medicare Advantage plans deserve a separate check, because their rules do not always follow either the Medicare fee-for-service rule or the commercial rule. Confirm per payer before the claim goes out, and record the answer in the payer record.
WHAT A HOME TEST CANNOT DO
A home sleep test cannot diagnose narcolepsy, REM sleep behavior disorder, or periodic limb movement disorder. None of the home test codes or channels records EEG, EOG or EMG, so none of them can stage sleep or detect REM onset. All three diagnoses require attended, in-lab polysomnography, and narcolepsy specifically requires a same-day multiple sleep latency test immediately following the overnight study. Ordering a home test against one of those diagnoses is a medical-necessity mismatch before it is a billing problem, and the claim will deny on coverage even if the code is perfectly chosen.
Many commercial plans and Medicare Advantage plans require a home test first unless the patient has a condition such as significant lung disease, heart failure, or a suspected non-apnea sleep disorder. When the patient does have one of those complicating conditions, the in-lab study is the right test from the start, and the prior authorization request should name the condition rather than sending the patient home with a monitor that cannot answer the question.
The multiple sleep latency test and the maintenance of wakefulness test both bill as 95805. An MSLT for suspected narcolepsy usually follows an overnight polysomnogram, and payers expect that overnight study on file, because proper interpretation of the MSLT can only be made following a polysomnography performed on the preceding night. Schedule the two studies as a pair: the overnight study first, the daytime MSLT the following day, both in the laboratory. A home test cannot substitute for the overnight study, because the MSLT interpretation depends on the staged overnight recording that only the laboratory study produces.
THE TECHNICAL AND PROFESSIONAL SPLIT: TC, 26 AND GLOBAL
Every sleep study code has a technical component and a professional component. The technical component covers the equipment, the technologist, the overnight recording, the device, the setup, the data download and the scoring support. The professional component covers the physician review of the raw data and the signed interpretation and report. Who performed each piece decides how the claim is built, and billing the wrong component is one of the most common sleep billing errors.
| Billing pattern | Who did what | How to bill |
|---|---|---|
| Global | The same practice ran the study and read it | The code with no modifier |
| Technical only | The laboratory ran the study; a separate physician reads it | The code with modifier TC |
| Professional only | The physician read a study run on someone else equipment | The code with modifier 26 |
| Hospital split | The hospital runs the laboratory; the interpreting physician is separate | Hospital bills the technical side on its facility claim; the physician bills with modifier 26 |
A physician-owned laboratory that employs the technologists and reads its own studies bills the global code, with no modifier. A freestanding laboratory that contracts out its reads bills with modifier TC, and the reading physician bills the same code with modifier 26. When a hospital runs the laboratory, the hospital bills the technical side on its own facility claim, and the interpreting physician bills with modifier 26. The same split applies to home tests: if the practice owns the device, dispenses it and interprets the study, it bills globally without a modifier; if it supplies the device but an outside physician interprets it, it bills TC only and the interpreting physician bills 26 separately.
Two rules prevent most split-billing denials. First, never bill globally when someone else owns the technical component: a global code billed for a study run on hospital equipment claims work the practice did not perform. Second, never report both 26 and TC on the same claim line. The professional component also needs its own support, a separate, signed written interpretation and report on file before the claim is submitted, and the place of service on a split claim should reflect where the equipment resides, not where the interpretation occurred.
THREE WORKED EXAMPLES
| Scenario | Correct claim | Why |
|---|---|---|
| Type III home monitor, four channels, traditional Medicare, practice supplied and read the study | G0399, global, no modifier | Monitor type and channel count match G0399; the same study to a CPT-accepting commercial payer would be 95806 |
| Seven-hour in-lab study, five additional parameters, titration begun halfway through the night | 95811 alone, global, no modifier | Titration was initiated, so 95811 includes the diagnostic portion; billing 95810 as well would deny as bundled |
| In-lab diagnostic study ended after four hours at the patient request, sleep staged, four additional parameters, no titration | 95810 with modifier 52 and a reduced charge | Recording ran less than six hours, so the reduced-services modifier and an explanation are required |
THE DOWNSTREAM PAYMENT: CPAP COVERAGE AND THE 12-WEEK TRIAL
The sleep study result decides whether CPAP is covered, and the study and the device travel through two different Medicare pathways. The study claim goes to the local Part A and B contractor under the polysomnography coverage article, while the CPAP device is a separate durable medical equipment claim with its own coverage rules and compliance gate. A denied study claim usually blocks the device claim behind it, because device coverage depends on a qualifying study.
Medicare covers CPAP for adults with obstructive sleep apnea under National Coverage Determination 240.4. The treating practitioner must examine the patient in person before the sleep test, and the test must be a qualifying study: an attended, facility-based polysomnogram, or an unattended home sleep test using a Type II, Type III or Type IV device that records at least three channels. The test result must meet one of two thresholds. An apnea-hypopnea index, known as AHI, or respiratory disturbance index, known as RDI, of 15 or more events per hour, with a minimum of 30 recorded events, qualifies on its own. An AHI or RDI of 5 to 14 events per hour, with a minimum of 10 recorded events, qualifies only with documented symptoms or conditions: excessive daytime sleepiness, impaired cognition, a mood disorder, or insomnia, or hypertension, ischemic heart disease, or a history of stroke. The AHI thresholds are confirmed in the Medicare CPAP coverage summaries at https://www.apria.com/medicarescreening and https://www.usehana.com/blog/medicare-cpap-qualification-sleep-test-criteria and both agree on the two paths and the minimum event counts.
Coverage starts with an initial 12-week trial period, often described as a 90-day trial. Continued coverage after the trial is a separate step, and it requires two things: the practitioner documents benefit from CPAP during the trial period, and the patient meets the adherence standard. Adherence is defined as use of the CPAP device for at least four hours per night on 70 percent of nights during a consecutive 30-day period within the preceding 90 days. A patient who fails the 12-week trial needs an in-person reevaluation and a repeat facility-based sleep study before a new trial can start. The compliance data comes from the device itself, and the practice needs a process to collect it, review it, and act on it before the trial period ends, not after coverage has already lapsed.
The device side of this story belongs to durable medical equipment billing, and this article does not repeat it. For the CPAP device documentation, supplier standards and claim rules, see our guide to DMEPOS billing at https://neximedbilling.com/blog/dmepos-billing-medicare-documentation-requirements/
DENIALS: WHAT GOES WRONG AND HOW TO FIX IT
Most sleep study denials fall into a small set of patterns, and each one maps to a specific fix. The denial guide at https://neximedbilling.com/blog/claim-denial-codes-complete-guide/ explains the denial code system in full. The table below applies that system to sleep studies specifically.
| Denial pattern | What the payer saw | Fix |
|---|---|---|
| Wrong code set for the payer | CPT home test code sent to a Medicare contractor that requires G0398, G0399 or G0400 | Rebill with the G-code that matches the monitor type; add the payer rule to the payer matrix |
| Same-night bundling | 95810 and 95811 billed for the same night | Bill 95811 alone for a split-night or titration night; correct the claim |
| Short recording without modifier 52 | A study under six hours billed as a full study | Append modifier 52 with a reduced charge and a note explaining why the study ended early |
| Global billing when the practice does not own the technical component | A global code for a study run on hospital equipment | Split the claim: hospital bills the technical side, the physician bills with modifier 26 |
| MSLT without the overnight study | 95805 billed with no preceding overnight polysomnogram | Schedule the overnight study and the MSLT as a pair; do not bill the MSLT alone |
| Home test for a diagnosis it cannot evaluate | A home test ordered for narcolepsy, REM sleep behavior disorder, or periodic limb movement disorder | Order the in-lab study the diagnosis requires; document the reason |
| Wrong G-code for the monitor type | A Type III study billed as G0398, claiming seven channels never recorded | Match the G-code to the channels in the downloaded data, not to the device label |
A denied sleep study claim should be worked from the remittance advice, not from memory. Read the adjustment reason code and the remark code, and match both to the table above before deciding whether to correct the claim, appeal it, or write it off. A code-set denial is corrected and rebilled, and a medical necessity denial is appealed with documentation.
WHAT CHANGES ON 1 JANUARY 2027: THE HOME TEST CODES ARE DELETED
The home test CPT codes have an end date, and 2026 is the year to prepare for it. CPT codes 95800, 95801 and 95806 are deleted effective 1 January 2027, replaced by a six-code family that splits technical and professional work by complexity tier. The American Academy of Sleep Medicine announced the change and published guidance on the new framework at https://aasm.org/new-2027-cpt-guidance-for-unattended-sleep-testing-now-available/ and CMS finalized the Medicare payment values for the new codes in the calendar year 2027 Physician Fee Schedule final rule.
| Tier | Technical code | Interpretation code | Basis |
|---|---|---|---|
| Low | 95843 | 95847 | 3 to 4 channels, at least 3 to 5 parameter categories |
| Moderate | 95844 | 95848 | 5 to 10 channels, at least 6 to 8 parameter categories |
| High | 95846 | 95849 | 11 or more channels, at least 9 parameter categories |
The three technical codes cover setup, data acquisition and technical analysis, and the three interpretation codes cover interpretation and report. Code selection is based on the number of clinically relevant channels recorded and the number of parameter categories generated, with the lower of the two determining the appropriate complexity level. The three current codes stay billable for dates of service through 31 December 2026. From 1 January 2027, every home sleep test billed under CPT moves to the new structure, and a charge master that still holds 95800, 95801 or 95806 will start denying on invalid code.
Attended in-lab polysomnography is not part of this replacement. Codes 95807, 95808, 95810 and 95811 continue. Authorizations written on 95800 or 95806 will not match the new codes, so authorizations for January dates of service need to be checked and reissued under the new code set before the study date, not after the claim denies. The new codes also change who bills which component, because the technical and professional work are now separate codes rather than one code split by modifier, so a practice that bills globally today must decide how it bills the two new codes before January.
One open question remains: the calendar year 2027 final rule does not address whether Medicare will still accept G0398, G0399 and G0400 after the CPT replacement, and no CMS guidance reviewed for this article answers it. Billing teams should ask their Medicare Administrative Contractor in writing whether it still accepts the G-codes for 2027 dates of service. Do not assume the G-codes continue, and do not assume they end.
CHECKLIST: BEFORE THE CLAIM GOES OUT
- Read the report for where the study happened, and confirm it was a facility-based laboratory for any 95807, 95808, 95810 or 95811 claim.
- Count the channels actually recorded, beyond EEG, EOG and chin EMG, and match the count to 95808, 95810 or 95811.
- Confirm whether titration was initiated during the night, and bill 95811 alone if it was.
- Check the recording time, and append modifier 52 with a reduced charge and an explanation if it ran for less than six hours.
- For a home test, identify the payer first, then choose the G-code or the CPT code that payer requires, and match the G-code to the monitor type and channel count.
- Confirm the face-to-face evaluation by the treating practitioner happened before the test, and that the comprehensive sleep evaluation and the instruction on applying the device are documented.
- Confirm who ran the study and who read it, and bill globally, with modifier TC, or with modifier 26 to match that reality, with a signed interpretation on file.
- Confirm the diagnosis supports the test ordered, and that a home test was not ordered for a diagnosis it cannot evaluate.
- For a CPAP device that follows, confirm the AHI or RDI threshold and the minimum event count, and start the adherence tracking on the first day of the 12-week trial.
- For January 2027 dates of service, confirm the new home test codes are loaded in the charge master, the old codes are retired by date of service, and authorizations name the new codes.
MISTAKES THAT WILL COST A SLEEP PRACTICE
- Billing 95810 for a home study: the code requires a facility-based laboratory, and no modifier cures a home setting.
- Billing 95810 and 95811 together for a split night: 95811 already includes 95810 for that night.
- Sending CPT home test codes to Medicare without checking the contractor rule: the G-code is accepted everywhere Medicare home testing is covered.
- Billing globally for a study run on someone else equipment: split the claim with modifier TC and modifier 26 instead.
- Ordering a home test for narcolepsy or a related disorder: the monitor cannot stage sleep, so it cannot answer the question.
- Letting a short study go out as a full study: append modifier 52 with a reduced charge and an explanation.
- Treating the CPAP trial as automatic after a qualifying study: the 12-week trial has its own adherence gate.
- Entering 2027 with a charge master that still holds the deleted home test codes: January denials will say invalid code.
FREQUENTLY ASKED QUESTIONS
Can 95810 be billed for a home sleep study?
No. CPT 95810 describes attended polysomnography in a facility-based sleep laboratory, for at least six hours, with sleep staging and four or more additional parameters. A home study bills from the home test family instead: G0398, G0399 or G0400 for Medicare, or 95800, 95801 or 95806 for payers that accept CPT.
How is a split-night sleep study billed?
As 95811 alone, which covers polysomnography with CPAP or bilevel titration. The diagnostic portion is included, so 95810 is not billed for the same night. If no titration was initiated, and the study was purely diagnostic with four or more additional parameters, the code is 95810.
What codes does Medicare use for home sleep tests?
G0398, G0399 and G0400, matched to the monitor type: Type II, Type III and Type IV. G0398 requires a minimum of seven channels, G0399 a minimum of four, and G0400 a minimum of three. Commercial payers usually use CPT codes 95800, 95801 and 95806, but some commercial plans and Medicaid programs use the G-codes, so confirm the payer rule before the claim goes out.
What is the six-hour rule for polysomnography?
For a study to be reported as polysomnography, sleep must be recorded and staged and directly attended by a qualified technologist, for at least six hours of recording. If the recording ran for less than six hours, report the code with modifier 52 for reduced services, with a reduced charge and a note explaining why the study ended early.
Does a home sleep test qualify a patient for CPAP?
It can, if it is a qualifying study and the result meets the threshold. Medicare covers CPAP when the test shows an AHI or RDI of 15 or more events per hour, with a minimum of 30 recorded events, or 5 to 14 events per hour, with a minimum of 10 recorded events, plus documented symptoms or conditions such as excessive daytime sleepiness, hypertension, ischemic heart disease, or a history of stroke. Coverage starts with a 12-week trial, and continued coverage requires documented benefit and adherence of at least four hours per night on 70 percent of nights during a consecutive 30-day period within the preceding 90 days.
What happens to home sleep test codes in 2027?
CPT codes 95800, 95801 and 95806 are deleted effective 1 January 2027, replaced by six codes: technical codes 95843, 95844 and 95846, and interpretation codes 95847, 95848 and 95849, tiered by channels recorded and parameter categories generated. The current codes stay billable for dates of service through 31 December 2026. Attended in-lab codes 95807, 95808, 95810 and 95811 are not part of this change.
EDUCATIONAL DISCLAIMER
This article is educational information about sleep study billing rules. It is not billing advice, coding advice, or legal advice, and it does not replace the current CPT code set, the CMS billing and coding articles for polysomnography and sleep testing, the National Coverage Determination for CPAP, or the guidance of the practice Medicare Administrative Contractor. Code descriptors, coverage rules and payer requirements change, and the 2027 home test code replacement is one such change. Confirm how each code applies to the practice own studies, payers and contractors with the Medicare Administrative Contractor or a qualified billing adviser before submitting a claim.